2 - 188
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-6-07
Message Board Lamp Assignment
General Description
Use this Memory Block to assign mailbox numbers for each Message Display Board.
Display
Settings
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
NON
(Unassigned)
MSG
Programming Procedures
1
Go off-line.
2
Press LK1 + LK6
+
J
+
J
+
G
to access the Memory Block.
3
Press line key to select Setting Data 1. Use the dial pad to select Setting Data 2.
Use the following to enter data:
J
to move the cursor to the left
L
to move the cursor to the right
K
~
I
to enter numeric data
H
to clear all data
Setting Data 2: Mailbox No.
2-digits 10 ~ 89
3-digits 100 ~ 899
4-digits 1000 ~ 8999
4
Press
G
to write the selected data. The next Lamp No. is displayed. After all 48 lamps are assigned, the next Board No. is
displayed.
5
Repeat Steps 3 and 4 for each lamp (01~48) and for each board (1~8). The next Memory Block is displayed.
6
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
7-2
Telephone Type Assignment
System Mode
1
Submode
6
Data No.
07
PC Programming
¦
+BTB
0 7 :
1 – 0 1 N O N
T I M E
D I S P L A Y
Data
No.
Lamp
No.
Setting
Data 1
Setting
Data 2
Board