2 - 424
Memory Blocks
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
___________________________________________________________________________________
2-09
DID Limit to Tenant Assignment
General Description
Use this Memory Block to assign the number of DID calls allowed to ring at a specified
tenant.
Display
Notes
Programming Procedures
1
Go off-line.
2
Press LK2 +
KI
to access the Memory Block.
3
Enter Setting Data using the dial pad.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Default Values
00 (No Limit)
01~64 Incoming Calls
4
Press
G
to write the data. The next Tenant No. for Memory Block 2-01 is displayed.
5
Program all Tenants. After Tenant 47 is programmed, the display cycles back to Tenant 01 of Memory Block 2-01.
6
Press
E
to go back on-line.
Only DID incoming calls are limited. Outgoing calls, Internal (ICM) calls, and normal incoming calls are not
limited.
System Mode
2
Submode
—
Data No.
09
PC Programming
¦
+ BN
0 0 : 0 9 : L I M I T
0 0
T I M E
D I S P L A Y
Setting
Data 00~64
Data
No.
Title
Tenant
No.