H
Numbers affected by code restriction using Memory Block
1-1-82 (CO Feature Code Service for Code Restriction.), need
not be specified as 8-digit dialing numbers in the ARS table
because they are automatically excluded from ARS.
H
NORMAL origination in USA is Trunk Group 1.
H
When a dialing number is not subjected to ARS, it is either
originated according to the LCR bypass specification or busy.
H
When ARS begins checking a received number, a 10-second
timer is set. When timeout occurs, ARS ends and normal
origination is performed.
2.6
ARS Flowcharts
The flowcharts show how origination by Trunk Group 1 is determined.
When the call is not originated by pressing a line key or dialing a Trunk Group
1 access code and the LCR Class is 0, the call is originated as is.
When LCR Class 1, 2, 3, or 4 is selected the call is originated according to
bypass specifications in the class of service and becomes busy.