2 - 234
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-8-26
Voice Mail Quick Transfer Master
Hunt Number
General Description
Use this Memory Block to specify a Voice Mail Master Hunt Number to operate Quick
Transfer to Voice Mail. This Memory Block also enables the voice mail display in the
LCD of a Multiline Terminal when a voice mail machine sets a message.
R2500 or higher is required to assign a 5-, 6-, or 7-digit Master Hunt Number.
Display
(R1700 or lower)
Display
(R2000 or higher)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK8 +
BF
to access the Memory Block.
3
Use dial pad to enter agent station No
.
Use the following to enter data:
K
~
I
to enter numeric data
J
to move cursor left
L
to move cursor right
Station number is one of the following:
2 digit (10 ~89)
3 digit (100 ~ 899)
4 digit (1000 ~ 8999)
5 digit (10000 ~ 89999)
6 digit (100000 ~ 899999)
7 digit (1000000 ~8999999)
Default Values
Not Specified
4
Press
G
to write the data. The next Memory Block is displayed.
System Mode
1
Submode
8
Data No.
26
PC Programming
¦
+AV
2 6 : V M
M A S T E R 0 0 0
T I M E
D I S P L A Y
Station
No.
Title
Data
No.
2 6 : V M M S T R 0 0 0
T I M E
D I S P L A Y
Station
No.
Title
Data
No.