2 - 4
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-1-02
Hookflash Time Selection
General Description
Use this Memory Block to specify the loop open time for a hookflash signal sent to the
CO or PBX when the Recall key on a Multiline Terminal is pressed. A Single Line
Telephone (SLT) generates a hookflash to the CO or PBX line when a Single Line
Telephone hookflash is assigned.
Display
Settings
Page 1
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
20ms
40ms
60ms
80ms
100ms
140ms
160ms
200ms
Page 2
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
400ms
600ms
800ms
1.0s
1.5s
2.0s
3.0s
5.0s
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1
+
KB
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Use the following to enter data:
C
to go to the next page
A
to go to the previous page
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
1
Data No.
02
PC Programming
¦
+BCM
0 2 : F L S H 6 0 0 m s
| 2
T I M E
D I S P L A Y
Data
Setting
Title
Data
No.
Page
No.