Electra Elite IPK
Document Revision 4
Programming Manual
3 - 39
___________________________________________________________________________________
___________________________________________________________________________________
3.3.41
Call by Call Simulated Facility Group Assignment (Memory Block
1-10-09)
Use this Memory Block to specify a Simulated Facility Group (01~16)
to control SFGs of each facility for each RAB.
Default: All RABs 00 (None)
SFGs for FX can be defined per FX Facility Group for incoming,
outgoing, and Incoming/outgoing calls using an FX Facility Group.
SFGs for Tie Trunks can be defined per Tie Trunk Facility Group for
incoming, outgoing, and Incoming/outgoing calls using a Tie Trunk
Facility Group.
SFGs for OUTWATS can be defined for outgoing calls per individual
OUTWATS service. For IntraLATA and banded OUTWATS, an SFG
is assigned to each band. For InterLATA OUTWATS, an SFG is
assigned to each IC.
SFGs for INWATS can be defined for incoming calls per INWATS
called DN.
3.3.42
Call by Call Outgoing SFG Assignment (Memory Block 1-10-20)
Use this Memory Block to specify an outgoing SFG for each SFG
specified by Memory Block 1-10-09.
Default: 99
3.3.43
Call by Call Outgoing/Incoming SFG Assignment (Memory Block
1-10-21)
Use this Memory Block to specify an Outgoing or Incoming SFG for
each SFG specified by Memory Block 1-10-09. The incoming SFG
is controlled by the network.
Default: 99
3.3.44
Call by Call Incoming Type Selection (Memory Block 1-10-22)
Use this Memory Block to specify an Incoming Call Type for each
SFG specified by Memory Block 1-10-09 as either CO (Normal) or
DID.
Default: DID