2 - 84
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1
+
FC
to access the Memory Block.
3
Use the dial pad to enter the Data Setting for Class 1.
Setting Data
000s~999s (e.g., 020s = 20s)
Default Values
Class 1~4 = 060s
000s = No Limit
4
Press
G
to write the data and display the next Timer Class of Service.
5
Program the next Timer Class of Service or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-03
Hold Recall Time Selection (Non-Exclusive Hold)
1-2-23
System Call Park Recall Time Selection
4-71
Station to Timer Class of Service (R3000 or higher)
1.
When an Exclusive Hold call recalls, the held call switches to a Non-Exclusive Hold call.
2.
Telephone ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station
to Timer Class of Service, Class 2 by default
(R3000 or higher)
.
3.
When a system is upgraded from R2500 or lower to
R3000 or higher,
the Hold Recall Time Selection is reset to
the default value during the upgrade process
.
6 3 : H L D R C L
1 = 0 6 0 s
T I M E
D I S P L A Y
Timer
Class
1~4
Title
Data
No.
Setting
Data