Hydro-Pro

Environmental Control System

www.babala-hydroponics.cn

www.pro-leaf.com

Instruction Manual

Содержание Hydro-Pro

Страница 1: ...Hydro Pro Environmental Control System www babala hydroponics cn www pro leaf com Instruction Manual...

Страница 2: ...V Overview of Hydro Pro System Specifications of Hydro Pro Series Products Warings Cautions Avertissement Pr cautions Installation Instructions Installation Diagram VI VII Operation Instructions 1 In...

Страница 3: ...Hydro Pro allows you to select the type of light LED or HID to be controlled and can simultaneously employ 2 channels of independent or interlocked light control logic in different modes to create mu...

Страница 4: ...utput ports RJ12 RJ12 x 4 4 channel RS485 communication Signal line output DC24V 1 0A Network port RJ45 Dimensions 14 H x 17 W x 4 D excluding length of power cable Power cord length 2m 6 5ft Net weig...

Страница 5: ...ty accuracy 2 RH Temperature range 0 70 Temperature accuracy 0 5 Maximum quantity 4pcs per unit Communication mode RS485 Modbus RTU Light Sensor Photocell Main parameters Default values Working voltag...

Страница 6: ...er 1100W Communication terminal RJ12 connector Indicator Green LED Maximum connections quantity 32pcs Communication Mode RS485 Modbus RTU Main parameters Default values Input Voltage DC24V Output Volt...

Страница 7: ...cket is consistent with the parameter described Pr cautions Avant d ins rer le Contr leur principal Hydro pro v rifiez que la tension de la prise correspond aux param tres d crits Cautions After the e...

Страница 8: ...e controller and connect the corresponding devices accordingly Heat Cool Humidify Humidify Dehumidify 01 02 03 04 05 06 07 08 09 10 Dehumidify Light 1 Light 2 Alarm Alarm 2 Loosen the screw on the con...

Страница 9: ...onnected to the probe socket on the bottom of the Hydro Pro Master Controller and check if the connector is properly inserted Place the probe of the light sensor in the place to be measured with its f...

Страница 10: ...V Installation Diagram 4x CO2 Sensor Lights Lights Net Power AC 110V USB TF Reset 4x Humidity Temp Sensor CO2 Tank CO2 Generator Fan Devices Devices Distribution box Dehumidifier 9...

Страница 11: ...box or related equipment that supports AC24V signals 6 Before the connection it is necessary to check if the positive and negative poles of the output line are correct After the circuit connection is...

Страница 12: ...related devices are displayed on the interface including VPD humidity temperature CO2 light day and night 10 49 05 11 01 2020 DaytimeMode LIGHT ON at 08 00 OUTPUT MAX 80 OFF at 18 00 Type LED HUMI CLI...

Страница 13: ...ad by the sensor the humidity in the environment can be controlled and adjusted The humidity is controlled within a range That is when the humidity is below the humidification value the humidifier AC2...

Страница 14: ...be used immediately out of the box The Hydro Pro controller will display the date symbol in the upper left corner of the day night mode Day mode control The Hydro Pro controller outputs signals to the...

Страница 15: ...uding VPD humidity temperature CO2 light day and night The day and night status is displayed in the upper left corner of the interface and the current time and date are displayed in the top middle pos...

Страница 16: ...n navigate to other related interfaces via the interface on the right side Time format Set the date format as MM DD YYYY and the time format as HH MM SS 12 24 hour time format 12 hour and 24 hour time...

Страница 17: ...D connection status online offline will be displayed simultaneously In this interface you can choose to find unregistered devices 2 2 Adding sensors or devices In this interface you can delete or find...

Страница 18: ...evice list The RS485 port for the sensor is the Sensor port The RS485 port for the device is the Device port The RS485 port for the LDA 1 device is the Light LINE 1 or Light LINE 2 port 2 3 Deleting s...

Страница 19: ...ower left corner the temperature value heating on value cooling on value and the corresponding Deadband value are displayed In the upper right corner the target value of CO2 Deadband value and high CO...

Страница 20: ...TEM SETTING CONNECTION STATUS 5 CO2 Setting In the CO2 setting interface the real time data of the currently connected sensor are displayed as well as the device s CO2 parameters set such as working m...

Страница 21: ...which a dialogue box will pop up prompting you to save the data the data modified will not take effect unless they are saved 5 2 Default parameters 5 3 Day and night setting The device will not start...

Страница 22: ...ce will display the specific working status of the device In different modes different icons are used to display the current working status 5 6 Interlock settings When performing actions the working s...

Страница 23: ...umidity protec tion value target value and deadband value After the data are set the Save button will light up At this time press the Save button to save the data after which a dialogue box will pop u...

Страница 24: ...idify mode the device will turn on the dehumidification output port when the current value is higher than Dehumidify value and immediately turn off the dehumidification output port when the humidity v...

Страница 25: ...vice are displayed in the upper part of the device If the device is not equipped with a temperature and humidity module the relevant temperature and humidity data of the 3 in 1 module will be used Mea...

Страница 26: ...fication High Temp Protection value The value set needs to be higher than the Cool target value of heating After the data are set the Save button will light up At this time press the Save button to sa...

Страница 27: ...heating output port when the real time tempera ture value is higher than Heat Deadband value The device will turn on the dehumidification output port when the current value is higher than Cool value...

Страница 28: ...ool 15 0 Deadband IRRIGATION STATUS Auto 08 30 60 18 30 HID FOLLOW MODE CO2 PPM 1100 Deadband 200 Target 1200 High CO2 PPM Protection 5000 SYSTEM SETTING CONNECTION STATUS 8 Light Setting On the home...

Страница 29: ...or the response is enabled again which is from 3min to 180min 8 4 Sun r s parameter setting In the interface the Sun R S mode can be enabled and disabled as appropriate that is a fixed off time can be...

Страница 30: ...minimum light intensity of 10 and a maximum light intensity of 115 LIGHT MODE LED HID ON Time at 8 00 HID Delay 3min 180min Sun R S 0 60min following the main line setting OFF TEMP 10 0 70 Output Max...