Chapter 7. Usage of Various Functions
7-64
4) Scaling function (for G7F-DA2I)
Scaling is the function that changes the offset and gain value for an easy operation.
•
Changing method is as below.
Scaling conversion value
800
4000
3200)
value
input
(Digital
+
×
=
Example) Digital value 1000 input in a range of 0 ~ 20
㎃
•
Before the scaling conversion (current range 0 ~ 20mA):
5mA
4000
20
1000
4000
20)
value
input
(Digital
=
×
=
×
•
After the scaling conversion (current range 4 ~ 20mA):
8mA
5μA
1600
800
4000
3200
1000
800
4000
3200)
value
input
(Digital
=
×
=
+
×
=
+
×
5) Wiring
(1) Caution for wiring
•
Make sure that external input signal of the mixture module of AC and analog I/O is not affected by induction noise or
occurs from the AC through using another cable.
•
Wire is adopted with consideration about peripheral temperature and electric current allowance. For wire, thicker than
AWG22 (0.3
㎟
) one is recommended.
•
If wire is put near to high temperature radiated device or contacted with oil for a long time, it may cause of electric
leakage so that it gets broken or miss-operation during wiring.
•
Be sure to connect with care of polarity while connecting to external 24V DC power supply.
•
In case of wiring with high voltage line or generation line, it makes induction failure so then it may cause of miss-
operation and out of order.
4000
0
0 ㎃
20 ㎃
4000
0
4 ㎃
20 ㎃
Resolution: 20
㎃
/4000 = 5
㎂
Resolution: 20
㎃
/3200 = 6.25
㎂
800
Содержание GLOFA G7M-DR20U
Страница 28: ...Chapter 4 Names of Parts 4 3 2 G7M DRT60U N 3 G7M DT60U N 4 G7M DT60U P...
Страница 29: ...Chapter 4 Names of Parts 4 4 5 G7M DR60U DC 6 G7M DRT60U N DC 7 G7M DT60U N DC...
Страница 30: ...Chapter 4 Names of Parts 4 5 8 G7M DT60U P DC 4 1 2 40 point main unit 1 G7M DR40U 2 G7M DRT40U N...
Страница 31: ...Chapter 4 Names of Parts 4 6 3 G7M DT40U N 4 G7M DT40U P 5 G7M DR40U DC...
Страница 32: ...Chapter 4 Names of Parts 4 7 6 G7M DRT40U N DC 7 G7M DT40U N DC 8 G7M DT40U P DC...
Страница 33: ...Chapter 4 Names of Parts 4 8 4 1 3 30 point main unit 1 G7M DR30U 2 G7M DRT30U N 3 G7M DT30U N...
Страница 34: ...Chapter 4 Names of Parts 4 9 4 G7M DT30U P 5 G7M DR30U DC 6 G7M DRT30U N DC...
Страница 35: ...Chapter 4 Names of Parts 4 10 7 G7M DT30U N DC 8 G7M DT30U P DC 4 1 4 20 point main unit 1 G7M DR20U...
Страница 36: ...Chapter 4 Names of Parts 4 11 2 G7M DRT20U N 3 G7M DT20U N 4 G7M DT20U P...
Страница 37: ...Chapter 4 Names of Parts 4 12 5 G7M DR20U DC 6 G7M DRT20U N DC 7 G7M DT20U N DC...
Страница 38: ...Chapter 4 Names of Parts 4 13 8 G7M DT20U P DC...
Страница 159: ...Chapter 7 Usage of Various Functions 7 52 c Program...
Страница 183: ...Chapter 7 Usage of Various Functions 7 76 c Program...
Страница 253: ...Chapter 8 Communication Functions 8 27 b When uses Ch 1 Built in RS 485...
Страница 355: ...Appendix 1 System Definitions App1 8 5 PID parameters 1 PID Auto Tuning Parameter 2 PID Parameter...
Страница 356: ...Appendix 1 System Definitions App1 9 6 Position Parameter...
Страница 357: ...Appendix 1 System Definitions App1 10 7 High Speed Counter Parameter...