A-10
PAT-T 4kW
A.3
Default Conditions
Table A-16 shows how the PAT is set when the *RST command is executed, at the
time of factory shipment, and when the power is turned on.
Table A-16 Conditions after sending a *RST and at po
w
er-on
See
Set
u
p item
Setting
Unit
F
u
nction
*RST
Factory
defa
u
lt
At po
w
er-on
OUTP
0/OFF
0/OFF
0/OFF
*1
–
O
u
tp
u
t on/off setting
OUTP:PO
N
:STAT
RST
*2
RST
Setting
immediately
before t
u
rning the
POWER s
w
itch off
–
O
u
tp
u
t condition at po
w
er-on
OUTP:EXT
N
ORM
N
ORM
–
Logical setting of the o
u
tp
u
t on/off
u
sing
external contact
VOLT
0
0
V
Voltage setting
VOLT:EXT:SOUR
N
O
N
E
*3
N
O
N
–
Control mode setting of constant voltage
VOLT:LIM:AUTO
0/OFF
0/OFF
–
Voltage limit setting
VOLT:PROT
111.5 % of the rated
o
u
tp
u
t voltage
V
OVP setting
VOLT:TRIG
0
0
V
Target voltage
u
sing a trigger
CURR
105.0 % of the rated
o
u
tp
u
t c
u
rrent
A
C
u
rrent setting
CURR:EXT:SOUR
N
O
N
N
O
N
–
Control mode setting of constant c
u
rrent
CURR:LIM:AUTO
0/OFF
0/OFF
–
C
u
rrent limit setting
CURR:PROT
111.5 % of the rated
o
u
tp
u
t c
u
rrent
A
OCP setting
CURR:TRIG
105.0 % of the rated
o
u
tp
u
t c
u
rrent
A
Target c
u
rrent
u
sing a trigger
OUTP:TRIG
0/OFF
0/OFF
–
Setting of
w
hether to t
u
rn the o
u
tp
u
t on/
off
u
sing a trigger
TRIG:SOUR
BUS
*4
BUS
BUS
–
Seq
u
ence 1 trigger so
u
rce
TRIG:SEQ2:DEL:O
N
/
TRIG:OUTP:DEL:O
N
0.0
0.0
Setting
immediately
before t
u
rning the
POWER s
w
itch off
S
O
u
tp
u
t on delay setting
TRIG:SEQ2:DEL:OFF /
TRIG:OUTP:DEL:OFF
0.0
0.0
S
O
u
tp
u
t off delay setting
TRIG:SEQ2:SOUR /
TRIG:OUTP:SOUR
BUS
BUS
BUS
–
Seq
u
ence 2 trigger so
u
rce
TRIG:SEQ3:SOUR /
TRIG:ACQ:SOUR
IMM
*5
IMM
IMM
–
Seq
u
ence 3 trigger so
u
rce
I
N
IT:CO
N
T:SEQ3 /
I
N
IT:CO
N
T:
N
AME ACQ
0/OFF
0/OFF
0/OFF
–
Seq
u
ence operation a
u
to contin
u
e mode
of seq
u
ence 3
SYST:CO
N
F:BTR:PROT
0/OFF
0/OFF
Setting
immediately
before t
u
rning the
POWER s
w
itch off
–
Breaker trip setting
w
hen the OVP or
OCP is activated
SYST:CO
N
F:BTR:SHUT
0/OFF
0/OFF
–
Breaker trip setting
w
hen the SD signal is
applied
SYST:CO
N
F:MSL
MAST
MAST
–
Stat
u
s setting d
u
ring parallel operation
SYST:CO
N
F:PAR
N
o change
1
–
Setting the n
u
mber of
u
nits in Master-
Slave Parallel Operation
SYST:CO
N
F:PST
N
ORM
*6
N
ORM
–
Stat
u
s signal setting of the o
u
tp
u
t on/off
SYST:CO
N
F:SPH
0/OFF
0/OFF
–
Setting the phase inp
u
t mode (Single-
phase/Three-phase)
SYST:CO
N
F:TRAC
N
o change
0/OFF
–
Comm
u
nication error display/hide setting
SYST:KLOC
–
Panel operation lock
MEM:KLOC
1/O
N
–
Preset memory recall setting
w
hile locked
*1.
The PAT may po
w
er
u
p at 1/O
N
depending on the OUTP:PO
N
:STAT setting.
*2.
RST: O
u
tp
u
t t
u
rns off at po
w
er-on.
*3.
N
O
N
E: Panel control
*4.
BUS: Wait for a soft
w
are trigger to start the meas
u
rement
*5.
IMM: Start the meas
u
rement immediately
*6.
N
ORM: O
u
tp
u
t a lo
w
level signal
w
hile the po
w
er is on.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...