PAT-T 4kW
9-3
9
Spec
ifica
tions
Output specifications
PAT20-200T
PAT40-100T
PAT60-67T
PAT160-25T
Rating
O
u
tp
u
t po
w
er
three-phase inp
u
t mode
4 kW
single-phase inp
u
t mode
3 kW
O
u
tp
u
t voltage
20.00 V
40.00 V
60.00 V
160.0 V
O
u
tp
u
t c
u
rrent
*1
*1.
In the single-phase inp
u
t mode, the o
u
tp
u
t c
u
rrent is limited to 75 % of the rating of three-phase inp
u
t mode.
200.0 A
100.0 A
67.0 A
25.0 A
Voltage
Preset range
*2
*2.
The maxim
u
m preset voltage and c
u
rrent are
u
sed to determine constant voltage or constant c
u
rrent operation
w
hen
the activation point of the constant voltage or constant c
u
rrent operation is set to the rated o
u
tp
u
t voltage or c
u
rrent. It
does not g
u
arantee po
w
er s
u
pply to the load exceeding the rated o
u
tp
u
t voltage or c
u
rrent.
To establish a constant voltage operation at the activation point (rated o
u
tp
u
t voltage or c
u
rrent), set the o
u
tp
u
t c
u
rrent
(I Set) so that rated o
u
tp
u
t c
u
rrent < I Set
≤
maxim
u
m preset c
u
rrent.
Like
w
ise, to establish constant c
u
rrent operation, set the o
u
tp
u
t voltage (V Set) so that rate o
u
tp
u
t voltage < V Set
≤
maxim
u
m preset voltage.
0 % to 105 % of rtg
Setting acc
u
racy
*3
*3.
The difference bet
w
een the act
u
al o
u
tp
u
t voltage or o
u
tp
u
t c
u
rrent and the preset val
u
e
u
nder constant voltage or
constant c
u
rrent operation.
± (0.2 % of rtg + 50 mV)
So
u
rce effect
*4
*4.
O
u
tp
u
t voltage or o
u
tp
u
t c
u
rrent fl
u
ct
u
ation
w
ith respect to ±10 % fl
u
ct
u
ation of the nominal inp
u
t voltage
u
nder constant
voltage or c
u
rrent operation.
± (0.05 % of rtg + 5 mV)
Load effect
*5
*5.
O
u
tp
u
t voltage or o
u
tp
u
t c
u
rrent fl
u
ct
u
ation
w
hen the o
u
tp
u
t voltage or o
u
tp
u
t c
u
rrent is set to the rated o
u
tp
u
t voltage
or c
u
rrent and the load is changed from rated load to no load
u
nder constant voltage or c
u
rrent operation.
± (0.1 % of rtg + 5 mV)
Transient response
*6
*6.
The time it takes for the o
u
tp
u
t voltage fl
u
ct
u
ation to recover from o
u
tside 0.1 % + 10 mV of the o
u
tp
u
t voltage setting
to
w
ithin 0.1 % + 10 mV
w
hen the o
u
tp
u
t c
u
rrent is changed from 100 % to 50 % or 50 % to 100 % of the rated o
u
tp
u
t
c
u
rrent
u
nder constant voltage operation. The o
u
tp
u
t voltage
w
hen the o
u
tp
u
t c
u
rrent is 100 % is
u
sed as a reference.
5 ms
Ripple noise
(p-p)
*7
*7.
When the meas
u
rement freq
u
ency band
w
idth is 10 Hz to 20 MHz.
100 mV
300 mV
350 mV
(rms)
*
8
*
8
.
When the meas
u
rement freq
u
ency band
w
idth is 5 Hz to 1 MHz for the o
u
tp
u
t voltage from 10 % to 100 % of the rating.
10 mV
30 mV
Rise time (MAX)
*9
*9.
The time it takes for the o
u
tp
u
t voltage to rise from 10 % to 90 % of the rating
w
hen the o
u
tp
u
t is t
u
rned on.
rated load
100 ms
no load
100 ms
Fall time (MAX)
*10
*10. The time it takes for the o
u
tp
u
t voltage to fall from 90 % to 10 % of the rating
w
hen the o
u
tp
u
t is t
u
rned off.
rated load
100 ms
no load
2000 ms
Temperat
u
re coefficient (MAX)
*11
*11. When the ambient temperat
u
re is
w
ithin the range of 0
°
C to 50
°
C.
100 ppm/
°
C (d
u
ring external control)
C
u
rrent
Preset range
three-phase inp
u
t mode
0 % to 105 % of rtg
single-phase inp
u
t mode
0 % to 105 % of rtg x 75 %
Setting acc
u
racy
± (0.5 % of rtg + 50 mA)
So
u
rce effect
± (0.1 % of rtg + 30 mA)
Load effect
± (0.2 % of rtg +30 mA)
Ripple noise (rms)
400 mA
300 mA
250 mA
200 mA
Temperat
u
re coefficient (TYP)
200 ppm/
°
C (d
u
ring external control)
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...