7-1
8
PAT-T 4KW
*PSC
IEEE 4
88
.2-1992
Section 10.25
Sets whether to clear the event status enable register and the service request enable
register when the POWER switch is turned on (power-on status).
Command
*PSC <NR1>
*PSC?
Parameter
Val
u
e:
0
Does not clear the *ESE and *SRE settings when the
POWER switch is turned on.
1
Clears the *ESE and *SRE settings when the POWER
switch is turned on.
An SCPI error (-222, “Data out of range”) occurs if outside the
range.
(Example)
To enable the power-on SRQ function
*PSC 0;*SRE 32;*ESE 128
Response
Returns the power-on status setting in response to *PSC?
*RST
Aborts the measurement operation and initializes the PAT to factory default
condition.
For the commands that are affected by *RST, see Table A-16.
Command
*RST
See
See