PAT-T 4KW
7-13
7
Remot
e
Cont
ro
l
7.5.2
Parameters
The parameter format of SCPI is derived from the program parameter format
defined in IEEE 488.2.
The representation system of the program data that is used on the PAT is indicated
below.
Non-numeric parameters
The PAT uses the following three types of non-numeric parameters.
Table 7-5
N
on-n
u
meric parameters
Numeric parameters
The PAT uses the following five types of numeric parameters.
Table 7-6
Nu
meric parameters
*1: Details are given in the “IEEE 4
88
.2 Standard Digital Interface for Programmable
Instr
u
mentation.”
Symbols or characters
Description
Character string data
(String)
Used
w
hen a series of ASCII characters are req
u
ested.
Be s
u
re to enclose a string in single q
u
otations or do
u
ble
q
u
otations. The start and end q
u
otation marks m
u
st match.
(Example)
FUNCtion “IMP”
If yo
u
w
ish to
u
se a q
u
otation mark as a part of the string, enter t
w
o
q
u
otation marks consec
u
tively (
w
ith no characters in bet
w
een).
ASCII codes 20H to 7EH can be
u
sed.
Character data
(Character)
Used
w
hen only a limited n
u
mber of val
u
es is available for the
program setting.
Responses are ret
u
rned in the short form.
(Example)
TRIGger:SOURce {BUS|IMMediate|TIMer}
Boolean data
(Boolean)
Expresses a 1 or 0 condition or an O
N
or OFF condition.
Responses are ret
u
rned as 1 or 0.
(Example)
OUTPut {ON|OFF|1|0}
Symbols or
characters
Description
N
R1
Represents an integer.*
1
N
R2
Represents a real n
u
mber (floating point).*
1
N
R3
Represents a real n
u
mber (exponential).*
1
The val
u
e +3.
8
0000+E02 is ret
u
rned for the response data 3
8
0. The
n
u
mber of digits of the decimal place is 5.
N
Rf
N
Rf is a generic term that incl
u
des
N
R1,
N
R2, and
N
R3.
Nu
meric
Represents a decimal point, optional sign, and meas
u
rement
u
nit.
The n
u
meric representation syntax is the same as
N
Rf.
MI
N
im
u
m and MAXim
u
m are available as s
u
bstit
u
tes for declaring
certain val
u
es.
Units s
u
ch as V, A, and W can also be
u
sed in a n
u
meric parameter.
If a val
u
e that cannot be assigned is entered, the device ro
u
nds the
val
u
e to the closest possible val
u
e.
(Example)
SOURce:CURRent 500
for PAT20-400T
The range of val
u
es for SOUR:CURR is 0 % to 105 % of the rated
o
u
tp
u
t c
u
rrent. Th
u
s, 500 is set even if 420 is specified.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...