PAT-T 4kW
5-7
5
Ext
e
rnal C
ontr
o
l
5.3.2
When the Output Terminal Is Grounded
If the positive output terminal is connected to the chassis terminal, the terminal is at
ground potential as shown in Fig.5-4. The cable and load that are connected to the
output terminal (including the sensing terminal) will only require an insulation
capacity that is greater than the maximum output voltage of the PAT with respect to
the chassis. There is no need to provide insulation greater than the isolation voltage
of the PAT.
The same holds true when the negative terminal is connected to the chassis terminal.
The cable and load require an insulation capacity that is greater than the maximum
output voltage of the PAT.
Fig.5-4
When the o
u
tp
u
t terminal is gro
u
nded
If the external voltage (Vext) output is grounded for the case shown in Fig.5-4, the
output is short-circuited (which can cause accidents).
For safety reasons, connect either output terminal to the chassis terminal unless your
application requires the output terminal to be floating.
11
18
17
13
14
12
16
21
20
19
23
22
15
10
1
24
25
26
+
+S
–S
–
+
–
10
11
9
18
17
13
14
12
16
21
20
19
23
22
15
7
8
1
AC
INPUT
DC
OUTPUT
J1
J2
SENS
+
–
+
–
Rext
V
ext
25
24
26
Since the + (pos.) output
terminal is at ground
potential, the section
indicated in gray must ha
v
e
an insulation capacity that is
greater than the maximum
output
v
oltage of the PAT
with respect to the chassis.
Insulated
Insulated
11 13 15 17 19 21 23
W
hen remote sensing is not used:
Connect to the negati
v
e output terminal
W
hen remote sensing is used:
Connect to -S terminal of sensing
J1 connector
Approx. the same potential as
the negati
v
e output terminal
Approx. the same potential as
the negati
v
e output terminal
Load
Chassis terminal wire
U
W
V
L
N
PAT
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...