PAT-T 4KW
7-47
7
Remot
e
Cont
ro
l
7.16.2 SCPI Register Model
OPERation status register
The OPERation status register is a 16-bit register which contains information about
conditions which are part of the PAT normal operation.
Table 7-11 OPERation stat
u
s register (STAT
u
s:OPERation)
STAT:OPER
Queries the event of the OPERation status register.
A query clears the contents of the register.
Command
STATus:OPERation[:EVENt]?
Response
Returns the event of the OPERation status register in the NR1 form.
Bit
Bit
Weight
Bit
N
ame
Description
0
1
N
OT USED
–
1
2
N
OT USED
–
2
4
N
OT USED
–
3
8
N
OT USED
–
4
16
MEAS
u
ring
Indicates
w
hether meas
u
rement is in
progress on the PAT.
5
32
Waiting for TRIGger
Indicates
w
hether the PAT is
w
aiting for a
trigger (TRIG).
6
64
N
OT USED
–
7
12
8
N
OT USED
–
8
256
CV
CV o
u
tp
u
t
9
512
N
OT USED
–
10
1024
CC
CC o
u
tp
u
t
11
204
8
N
OT USED
–
12
4096
ODEL (O
N
/OFF DELAY)
Indicates
w
hether the o
u
tp
u
t delay operation
is in progress.
13
8
192
ISUM
N
ot
u
sed
14
163
8
4
N
OT USED
–
15
3276
8
N
OT USED
–
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...