Processing time of Commands
The command processing time is the time until the next command is accepted.
The processing times specified below are typical values, and they are not warranted.
The processing time may vary depending on the setting conditions and measuring
conditions, and it does not include the response time of the hardware.
Table A-17 Processing time of main commands
A.5
Access and Operation for the Built-in Web
site (LAN interface)
For LAN interface, the detailed setting can be operated from the browser on the PC.
The URL of Web site is defined as adding "http://" in front of the IP address.
When VISA library is used, there is the function to retrieve the VXI-11 measuring
instrument by the application program provided by VISA vendors (National Instruments
NI-MAX, Agilent Connection Expert, and Kikusui KI-VISA Instrument Explorer, etc.).
Once you click on the web link from the retrieval result, the built-in Web site can be
opened.
The URL can be entered directly on the address bar of the browser by confirming
the IP address of the config setting (CF57 to CF60).
(Example) When the IP address is 169.254.7.8
http://169.254.7.8
The following browsers are applied.
•
Internet Explorer 5.5/6.0/7.0
•
Mozilla Firefox 2.0
•
Opera 9.0
•
Netscape 7.1
•
Safari 3.0
Command
GPIB
*1
Processing
Time (ms)
USB
Processing
Time (ms)
RS232C
*2
Processing
Time (ms)
LA
N
*3
Processing
Time (ms)
Description
OUTP
*4
25
ー
23
ー
O
u
tp
u
t on
6
ー
5
ー
O
u
tp
u
t off
VOLT 20
10
10
8
11
Sets the voltage.
MEAS:VOLT?
30
27
32
27
Q
u
eries the meas
u
red voltage
o
u
tp
u
t.
CURR
10
10
8
11
Sets the c
u
rrent.
MEAS:CURR?
2
8
27
32
27
Q
u
eries the meas
u
red c
u
rrent
o
u
tp
u
t.
*RST
102
102
100
102
Performs a device reset.
GET
*5
57
ー
ー
ー
IEEE4
88
.1 get message (Gro
u
p
Exec
u
te Trigger)
*1.
Using GPIB-USB-B by
N
ational Instr
u
ments.
*2.
Data rate setting: 3
8
400 bps. Flo
w
control: On
*3.
100BASE-TX Ethernet
*4.
The time co
u
nted from the receipt of command to activate the o
u
tp
u
t on/off.
*5.
A minim
u
m time of repeated operation
w
hen t
w
o
u
nits of the PAT are controlled.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...