A-6
PAT-T 4kW
Table A-9
IEEE4
88
.2 common commands
IEEE4
88
.2
common
command
Parameter
Description
R/W
*CLS
Clears all the event registers.
W
*ESE
N
R1
Sets the event stat
u
s enable register bits.
R/W
*ESR
Q
u
eries the event stat
u
s register.
R
*ID
N
Q
u
eries the identification string (man
u
fact
u
rer information).
R
*OPC
Ca
u
ses the device to generate the operation complete message in the
event stat
u
s register
w
hen all pending selected device operations have
been finished.
R/W
*OPT
Q
u
eries the hard
w
are interface board that is installed
R
*PSC
0 | 1
Initializes *ESE and *SRE.
R/W
*RST
Performs a device reset. Config
u
res the PAT to a kno
w
n condition
independent from the
u
sage history of the device.
W
*SRE
N
R1
Sets the service req
u
est enable register bits.
R/W
*STB
Reads the stat
u
s byte and master s
u
mmary stat
u
s bits.
R
*TRG
Trigger command
W
*TST
Exec
u
tes a self-test
R
*WAI
Prevents the device from exec
u
ting s
u
bseq
u
ent commands or q
u
eries
u
ntil the
N
o Operation Pending flag becomes tr
u
e.
W
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...