Load with accumulated energy
Connecting a load with accumulated energy, such as a battery, to the PAT may
cause current to flow from the load to the internal circuit of the PAT. This current
may damage the PAT or reduce the life of the battery.
For this type of loads, connect a reverse-current-prevention diode (D
RP
) between the
PAT and the load in series as shown in Fig.3-4.
This cannot be used in conjunction with remote sensing.
Fig.3-4
Remedy against load
w
ith acc
u
m
u
lated energy
•
Use a reverse-c
u
rrent-prevention diode (D
RP
) complied to the follo
w
ing
references.
Reverse voltage
w
ithstand capacity :
At least t
w
ice the rated o
u
tp
u
t voltage of the PAT.
For
w
ard c
u
rrent capacity :
Three to ten times the rated o
u
tp
u
t c
u
rrent of the PAT.
A diode
w
ith small loss.
•
Be s
u
re to take into acco
u
nt the heat generated by reverse-c
u
rrent-
prevention diode D
RP
. Reverse-c
u
rrent-prevention diode D
RP
may b
u
rn o
u
t
w
ith inadeq
u
ate heat dissipation.
PAT
Load
w
ith acc
u
m
u
lated
energy
D
RP
: Reverse-c
u
rrent-prevention diode
D
RP
CAUTION
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...