5-2
PAT-T 4kW
5.1
Overview of External Control
The J1 connector on the rear panel of the PAT can be used to perform external
control listed below.
•
Output voltage control
Control using external voltage or external resistance
•
Output current control
Control using external voltage or external resistance
•
Output on/off using external contact
•
Shutdown using external contact (turn off the output or POWER switch)
When the PAT is operating under external control, the EXT LED on the front panel
display illuminates.
Fig.5-1
Display example d
u
ring external control operation
5.2
J1 Connector
At the factory shipment, the protection socket is attached to the J1 connector. Keep
this protection socket and be sure to attach when the J1 connector is not used. If the
protection socket is damaged or lost, contact Kikusui distributor/agent.
Fig.5-2
Protection socket
Possible electric shock.
•
The J1 connector contains pins that are at the same electric
potential as the output terminal. If you are not using the J1
connector, be sure to insert the protective socket provided.
•
Be sure to use the protective cover on the sockets.
A connector kit is provided for connecting the J1 connector. The connector kit
consists of connector parts conforming to the MIL standard made by Omron.
The single contact connection tool and contact removal tool are not provided. Please
obtain your own tools.
For information on how to obtain the tools and consumable parts, contact your
Kikusui agent or distributor.
EXT
EXT
RMT
LOCK
PRESET A
B
C
A
V
OUTPUT
ALARM
CC
CC
Lights on
[
8
4-49-0110]
WARNING
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...