+ For details, see the transmit level sections of the installation chapter and the ap-
pendices.
XMITOK
{ON | OFF}
Multi-Port
default ON/ON
When ON, transmitting functions are enabled. If turned OFF, transmitting is in-
hibited while all other functions of the TNC are unchanged.
XOFF
n
(n = $00 - $FF)
default $13 <Ctrl+S>
This command selects the character sent by the TNC to the computer to stop in-
put from the computer. If set to $00 hardware flow control must be used. For
software flow control set this parameter to the character the computer expects to
see to stop sending data to the TNC.
See also:
xflow, xon
XON
n
(n = $00 - $FF)
default $11 <Ctrl+Q>
This command selects the character sent by the TNC to the computer to restart
input from that device. If set to $00 hardware flow control must be used. For
software flow control set this parameter to the character the computer expects to
see to restart sending data to the TNC.
See also:
xflow, xoff