SWP
u,d,t
default 17,17,108
This command sets the parameters used for software carrier detect. The first
number (u) is used to increment a counter when a valid mark/space or
space/mark transition occurs in the received signal (i.e. transition occurs at the
beginning of a bit time). The second number (d) is a penalty subtracted from the
counter when a transition occurs in the middle of a bit time. The t value is the
threshold value - when the counter total reaches this value, the carrier detect will
be set true. Once carrier detect is active, the counter must drop to 0 before carrier
detect is again made false.
The values need to be separated by commas as they are entered (as shown). Also
as shown, spaces between values are not necessary — but entering spaces after
the commas is OK.
See also:
cd
TRACE
{ON | OFF}
Multi-Port
default OFF/OFF
When ON, all received frames are displayed in their entirety, in hexadecimal, in-
cluding all header information. All packets which are eligible for monitoring also
will be displayed in normal text.
TRANS
immediate
This command causes immediate exit from Command Mode into Transparent
Mode. The current link state is not affected. There are no special editing charac-
ters, all characters are sent out as received. To get out of Transparent, send the
TNC a modem break if BREAK is ON, or see CMDTIME for a special keyboard
sequence.
Command Reference
TNC Commands
User’s Guide
276
KPC-9612 Plus v 8.2
Содержание KPC-9612 Plus
Страница 4: ...User s Guide ii KPC 9612 Plus v 8 2...
Страница 78: ...Installing Your KPC 9612 Plus User s Guide 62 KPC 9612 Plus v 8 2...
Страница 122: ...Getting Started Other Topics User s Guide 106 KPC 9612 Plus v 8 2...
Страница 214: ......
Страница 301: ...Command Reference KPC 9612 Plus v 8 2 285 User s Guide...
Страница 302: ......