external (soft) reset can not be connected to both Pin 7 and Pin 9 at the same
time.
Applying Power through the DB-9 connector.
To power the KPC-9612 Plus from Pin 7 of the DB-9 connector, you must con-
nect J2 center pin and pin 2, J3 center pin and pin 2.
Resetting the KPC-9612 Plus through the DB-9 connector.
To perform a soft reset from Pin 7 of the DB-9 connector, you must connect J2
center pin and pin 2, J3 center pin and pin 1. Momentarily applying a ground to
pin 7 will then perform a soft reset.
Alternatively, pin 9 can be used for either ground or reset with jumper J1: Con-
nect J1 center pin and pin 1 for ground, center pin and pin 2 for external reset.
Port 2: High Speed (e.g., 9600 Baud)
The connector labeled “Port 2" on the 9612 Plus rear panel is a 15-pin DB style
connector. The pin layout is presented in the ”Getting Started" chapter.
The purposes of each pin are as follows:
Pin
Pin
No.
name
Function
1
PTT
Push-to-Talk (output)
2
RXA
Receive signal (input)
3
TXA
Transmit signal (output)
4
RXD
Receive signal (digital input)
5
(not used)
6
CTLA 9600
Control line A (output) (High Speed
Port)
7
CTLB 9600
Control line B (output) (High Speed
Port)
8
RX S/N
Receive quality (output)
9
GND
Ground
10
GND
Ground
Appendix A: Advanced Installation
Connecting to your Radios
User’s Guide
294
KPC-9612 Plus v 8.2
Содержание KPC-9612 Plus
Страница 4: ...User s Guide ii KPC 9612 Plus v 8 2...
Страница 78: ...Installing Your KPC 9612 Plus User s Guide 62 KPC 9612 Plus v 8 2...
Страница 122: ...Getting Started Other Topics User s Guide 106 KPC 9612 Plus v 8 2...
Страница 214: ......
Страница 301: ...Command Reference KPC 9612 Plus v 8 2 285 User s Guide...
Страница 302: ......