Below
Product Overview
11
model
Constant torque
Variable torque
Output
power
(kW)
Input
current
(A)
Output
current
(A)
Output
power
(kW)
Input
current
(A)
Output
current
(A)
7R5G/011P-4
7.5
25
18.5
11
32
25
011G/015P-4
11
32
25
15
40
32
015G/018P-4
15
40
32
18.5
47
38
018G/022P-4
18.5
47
38
22
56
45
022G/030P-4
22
56
45
30
70
60
030G/037P-4
30
70
60
37
80
75
037G/045P-4
37
80
75
45
94
92
045G/055P-4
45
94
92
55
128
115
055G/075P-4
55
128
115
75
160
150
075G/090P-4
75
160
150
90
190
180
090G/110P-4
90
190
180
110
225
215
110G/132P-4
110
225
215
132
265
260
132G/160P-4
132
265
260
160
310
305
160G/185P-4
160
310
305
185
345
340
185G/200P-4
185
345
340
200
385
380
200G/220P-4
200
385
380
220
430
425
220G/250P-4
220
430
425
250
485
480
250G/280P-4
250
485
480
280
545
530
280G/315P-4
280
545
530
315
610
600
315G/355P-4
315
610
600
355
625
650
355G/400P-4
355
625
650
400
715
720
400G-4
400
715
720
/
/
/
450G-4
450
840
820
/
/
/
500G-4
500
890
860
/
/
/
Note:
1. The input current of the 0R7G
–315G/355P models is measured when the input voltage is 380V
and no DC reactor and input/output reactor.
2. The input current of the 355G/400P
–500G models is measured when the input voltage is 380V
and the circuit is with input reactor.
3. The rated output current is defined as the output current when the output voltage is 380V.
4. In the allowable voltage range, the output power and current cannot exceed the rated output
power and current in any situation.
3.7 Structure diagram
layout figure (taking the 030G/037P model for example).