ency, E08.45 and E08.46 can be set to increase or decrease the set frequency quickly.
support the shifting between different reference
Basic Operation Instruction
106
0
1
2
3
4
5
6
7
8
Keypad
AI1
MODBUS
PID
Multi-stage speed
Simple PLC
HDI
AI3
AI2
UP terminal
DOWN terminal
Digital
potentiometer
E08.44 tens place setting
(frequency control
selection)
E08.42 tens place setting
(frequency control
selection)
E17.13
Keypad digital
adjustment
E08.42 unit place
UP/DOWN
Digital potentiometer
enabling
E08.44 unit place
(UP/DOWN terminal valid
selection)
0, 1
UP/DOWN enabling
Digital potentiometer
enabling
0
E00.03
1
A frequency
command
+
+
(the Max. output frequency)
0
UP/DOWN enabling
0
valid
invalid
valid
Invalid
Terminal function 12
Frequency
increasing/decreasing setting
temporal clear
Terminal function 33
Frequency increasing/decreasing
setting temporal clear
0
0
1
2
3
4
5
6
7
8
Keypad
AI1
MODBUS
PID
Multi-stage speed
Simple PLC
HDI
AI3
AI2
E00.06
(A frequency command selection)
E00.07
(
B frequency command selection
)
E00.09
(the setting source combination)
E00.05 (the lower limit of the running
frequency)
E17.00
Setting
frequency
A
B
A+B
A-B
Max
(
A
,
B
)
Min
(
A
,
B
)
+
+
E17.02
Ramp given
frequency
E00.08 (B frequency command reference
selection)
Keypad setting frequency
0
1
2
3
4
5
E00.10
E00.10
Keypad setting frequency
E00.04 (the upper limit of the running
frequency)
channels
and the
detailed shifting rules is as below:
Current
reference
channel
Multi-function
terminal function 13
Shifting from A
channel to B channel
Multi-function
terminal function 14
Shifting from
combination setting
to A channel
Multi-function terminal
function 15
Shifting from
combination setting to
B channel
A
B
/
/
B
A
/
/
A+B
/
A
B
A-B
/
A
B
Max(A,B)
/
A
B
Min(A,B)
/
A
B
Note:
"/" means the multi-function terminal is invalid under the current reference channel.
When multi-function terminals UP (10) and DOWN (11) are used to set the internal assistant
frequ
E00.09