support pulse counter which can input counting pulse through HDI
Basic Operation Instruction
110
If the vibration periods are longer than the set value of integration time (Ti), it is necessary to
prolong the integration time (Ti) to control the vibration for the strong integration.
? ? ?
? ? ?
? ?
? ? t
? ? ?
? ? ?
? ?
? ? t
Before adjustment
After adjustment
Time
Response
? ? ?
? ? ?
? ?
? ? t
Control short vibration
Short vibration period and the same set value with the derivation time (Td) mean that the derivation
time is strong. Shortening the derivation time (Td) can control the vibration. When setting the
derivation time as 0.00(ire no derivation control) is useless to control the vibration, decrease the
gain.
? ? ?
? ? ?
? ?
? ? t
? ? ?
? ? ?
? ?
? ? t
? ? ?
? ? ?
? ? t
? ?
Before adjustment
After adjustment
Response
Time
7.11 Pulse counter
terminal.
When the actual length is longer than or equal to the set length, the digital output
terminal
can output length arrival pulse signal and the corresponding length will be cleared automatically.