And then, will run from the starting
frequency is the starting frequency.
torque during starting. During the
original frequency during
G type is small one
available motor power of
can use G/P type, the
Function Parameters
40
Function
code
Name
Description
Default
value
Modify
power file than that of P type.
E00.18
Function
restore
parameter
0: No operation
1: Restore the default value
2: Clear fault records
3: Lock the keypad
Note:
The function code is restored to 0 after the
operation corresponding to the selected option is
performed.
Restoring to the default value will cancel the user
password. Exercise caution before using this
function.
When
=3, all the other function codes
except
are read only.
0
◎
E01 Group Start and stop control
E01.00
Start mode
0: Start directly: start from the starting frequency
1: Start after DC braking: start the motor from the
starting frequency after DC braking (set the
parameter
). It is suitable in the
cases where reverse rotation may occur to the low
inertia load during starting.
2: Start after speed tracking: start the rotating
motor smoothly after tracking the rotation speed
and direction automatically. It is suitable in the
cases where reverse rotation may occur to the big
inertia load during starting.
Note: This function is available for the 004G/5R5P
and higher models.
0
◎
E01.01
Starting
frequency of
direct start
Starting frequency of direct start means the
starting. See
Setting range: 0.00
–50.00Hz
0.50 Hz
◎
E01.02
Retention time
of the starting
frequency
Set a proper starting frequency to increase the
retention time of the starting frequency, the output
0.0s
◎