Number of Controllers shows the total number of
ServeRAID adapters and controllers found in the
server.
ServeRAID Controller Information Panel
When you select a ServeRAID controller from the Main
Tree, the following information appears in the Main Panel
on the right:
Controller Type shows the type of ServeRAID
controller, such as ServeRAID II, ServeRAID-3H, or
ServeRAID-3L.
BIOS Version shows the level of basic input/output
system code currently installed for the ServeRAID
controller.
Firmware Version shows the level of microcode
currently installed for the ServeRAID controller.
Physical Slot shows the actual physical slot location
for the ServeRAID controller; for example, PCI slot 4.
Battery Backup Write Cache provides information
about the optional battery-backup cache device.
Statements such as Installed, Not Installed, Defective,
or Replace Battery might appear for this feature.
Read-Ahead Cache Mode shows the current setting,
Enabled or Disabled, for the read-ahead cache mode.
(See page 89 for more information.)
Stripe-Unit Size shows the current setting of 8 KB,
16 KB, 32 KB, or 64 KB for the stripe-unit size. (See
“Interleave depth and stripe-unit size” on page 67 and
page 90 for more information.)
Rebuild Rate shows the current setting (High,
Medium, or Low) for the rebuild rate. (See page 89
for more information.)
Hot-Swap Rebuild shows the current setting,
Enabled or Disabled, for the hot-swap rebuild feature.
This feature is set to Enabled when the level of
ServeRAID firmware in use supports this feature.
Data Scrubbing shows the current setting, Enabled
or Disabled, for the data-scrubbing feature. This
feature is set to Enabled when the level of ServeRAID
firmware in use supports this feature. The
data-scrubbing feature continuously reads all sectors
of RAID level-1 and RAID level-5 logical drives “in the
background” while the system is running. If a
defective sector is found, it is automatically repaired.
With this feature Enabled, you no longer need to
synchronize RAID level-1 and RAID level-5 logical
drives on a weekly basis.
Auto-Synchronization shows the setting for this
feature. The auto-synchronization feature always
appears as Enabled when the level of ServeRAID
firmware in use supports this feature. (See page 91
for more information.)
Netfinity 5500 M20 - Type 8662
79
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...