Error Code/Symptom
FRU/Action
177, 178
(Security hardware error)
1. Run
Configuration/Setup
2. System Board
184
(Power-on password
corrupted)
1. Run
Configuration/Setup
2. System Board
185
(Drive startup sequence
information corrupted)
1. Run
Configuration/Setup
2. System Board
186
(Security hardware control
logic failed)
1. Run
Configuration/Setup
2. System Board
187
(VPD serial number not set.)
1. Set serial number in
Setup
2. System Board
188
(Bad EEPROM CRC #2)
1. Run
Configuration/Setup
2. System Board
189
(An attempt was made to
access the server with
invalid passwords)
1. Run
Configuration/Setup,
enter the
administrator
password
201
(Memory test error, see
“Memory settings” on
page 30)
If the server does not have
the latest level of BIOS
installed, update the BIOS
to the latest level and run
the diagnostic program
again.
1. DIMM
2. Processor Board
3. System Board
229
(Cache error)
1. Processor
2. Optional Processor
(if installed)
3. Processor Board
262
(DRAM parity configuration
error)
1. Run
Configuration/Setup
2. Battery
3. System Board
289
(DIMM has been disabled
the user or system, see
“Memory settings” on
page 30)
1. Run
Configuration/Setup,
if disabled by user
2. Disabled DIMM, if not
disabled by user.
3. Processor Board
301
(Keyboard or keyboard
controller error)
1. Keyboard
2. System Board
303
(Keyboard controller error)
1. Keyboard
2. System Board
Netfinity 5500 M20 - Type 8662
305
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...