Selecting write-back mode will provide the maximum
system performance.
Note
If the system does not start (boot) successfully after
three attempts, the default configuration is loaded,
disabling the cache.
PCI bus control:
Select PCI Bus Control to get the
following choices:
PCI-PCI Bridge Pre-fetching: Set PCI-PCI bridge
pre-fetching to Enabled for maximum performance.
If you experience problems running peer-to-peer
adapters, disable this function.
PCI Primary Bus 0 MLT: This setting is for the
primary bus 0 master latency timer (MLT). It can be
used to help tune performance of the server.
PCI Primary Bus 1 MLT: This setting is for the
primary bus 1 master latency timer (MLT). It can be
used to help tune performance of the server.
PCI Interrupt Routing: This choice can be used to
manually override the interrupts for PCI devices. Any
changes that you make in PCI Interrupt Routing will
not be reflected in the IRQ settings displayed in the
PCI Routing selection of the System Information
menu until you restart the server.
Memory settings:
Select this choice to manually
disable or enable a row of memory.
If a memory error is detected during POST or memory
configuration, the server can automatically disable the
failing row of memory and continue operating with reduced
memory capacity. If this occurs, you must manually
enable the row of memory after the problem is corrected.
Choose Memory Settings from the Advanced Setup
menu; then use the the Up Arrow (
↑
) or Down Arrow (
↓
)
key to highlight the row that you want to enable. Use the
Left Arrow (
←
) or Right Arrow (
→
) key to select Enable. If
you boot the system with the bad row empty, this choice
resets the row.
Advanced ISA settings:
Select this choice to select
the I/O recovery timer settings.
Virtual wire mode selection:
Select this choice to
change the virtual wire mode in which the server will start.
The default is virtual wire IOAPIC mode. Only select
virtual wire mode PIC mode to run non-SMP operating
systems, such as Novell NetWare 3.xx.
30
Netfinity Server HMM
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...