Replace:
Controller with the ServeRAID controller
number (1 to 8)
DriveNum with the logical drive number
(0 to 7)
Oparm with the optional parameter,
NOPROMPT, to override the user
prompt
SYNCH
Use the SYNCH command to synchronize the
parity information on redundant logical drives.
If the parity information is inconsistent, the
IPSSEND program will repair it automatically.
Supported operating systems: Windows NT,
OS/2, NetWare, OpenServer, UnixWare, and
DOS
Command:
IPSSEND SYNCH
Controller Scope DriveNum
Replace:
Controller with the ServeRAID controller
number (1 to 8)
Scope with Drive for a single logical
drive
DriveNum with the logical drive number
(0 to 7)
ServeRAID error-recovery commands:
The IPSSEND error-recovery commands include the
following:
GETSTATUS Use the GETSTATUS command to display
the current logical-drive status for the most
recent rebuild, synchronization, or
logical-drive migration. The status includes
such information as the remaining size of the
logical drive, the percentage completed for
the function in process, or information about
the most recently completed logical-drive
function.
Supported operating systems: Windows NT,
OS/2, NetWare, OpenServer, UnixWare, and
DOS
Command:
IPSSEND GETSTATUS
Controller
Replace:
Controller with the ServeRAID controller
number (1 to 8)
REBUILD
Use the REBUILD command to rebuild a
designated disk drive. This command is valid
for disk arrays that contain one or more
logical drives that are in the critical (CRT)
state. Progress is indicated during the
rebuild operation, but you can also use the
122
Netfinity Server HMM
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...