ServeRAID Startup Messages
During power-on self-test (POST), the ServeRAID adapter
or controller compares the stored configuration information
to the configuration that is actually present. If a
discrepancy exists, one or more status messages appear
after POST completes but before the operating system
loads.
Notes
1. When the ServeRAID adapter or controller
requires your input, a list of function keys will
appear below the message.
2. Where the
Action information tells you to start the
IBM ServeRAID configuration program, insert the
IBM ServeRAID Configuration Utility Diskette or
CD into the appropriate drive; then, restart the
server. The
Action information also provides
general information about the message.
3. Where
SID and ch appear in these messages,
SID shows the SCSI ID for the device and ch
shows the channel to which the device is
attached.
4. Where
m or n appears in these messages, a
number will appear in the actual message.
The following is a list of messages associated with the
ServeRAID subsystem.
Auto rearrange
Explanation: Auto rearrange is enabled or disabled.
Action: This is an information message. No action is required.
Following drives not responding
(old state:
new state:
ch:
SID)
Explanation: One or more drives did not respond to the
ServeRAID controller. This may occur if configured drives are
missing or are not ready.
Where:
old state
is the configured state of the drive.
new state
is the state that the ServeRAID adapter or
controller will assign to the drive.
ch
is the channel where the drive was located
previously.
SID
is the SCSI ID for where the drive was located
previously.
Examples of the possible state changes include:
Online to Defunct
(ONL: DDD: x:
y)
Ready to Empty
(RDY: EMP: x:
y)
Standby to Empty
(SBY: EMP: x:
y)
Rebuild to Defunct
(RBL: DDD: x:
y)
Hot-Spare to Defunct
(HSP: DHS: x:
y)
Standby Hot-Spare to Defunct (SHS: DHS: x:
y)
Action: Press one of the following keys:
318
Netfinity Server HMM
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...