Recoverable configuration error
Explanation: The configuration data stored in NVRAM
(Battery-Backup Cache) does not match the configuration data
stored in the EEPROM.
Action:
1. Press Ctrl
+
Alt
+
Del to restart the system.
2. Press CTRL+I during POST to enter the Mini-Configuration
program.
3. Select Advanced Functions from the Main Menu; then, select
Import Configuration from Drive(s).
WARNING:
n logical drives are critical; n logical drives are
offline.
Explanation: One or more hard disk drives have failed.
Action: Replace the defunct drives as soon as possible to prevent
data loss.
The server has an error due to a Blocked Logical Drive.
Explanation: One or more logical drives are in a blocked state. A
blocked logical drive cannot be accessed.
Action: Press F4 to unblock the logical drive, or press F5 to
continue without unblocking.
Unable to communicate with the controller
Explanation: The controller is not responding to commands.
Action: Reseat the controller. If the problem persists, replace the
ServeRAID controller.
Controller Reg. <x> test failed. Test Number: <y>
Explanation: The controller or embedded controller failed the
register test, where <x> is the register number and <y> is the test
number.
Action: Reseat the controller. If the problem persists, replace the
ServeRAID controller.
Controller hardware error
Explanation: The controller is not responding to commands.
Action: Reseat the controller. If the problem persists, replace the
ServeRAID controller.
BIOS not loaded no devices found - Installation stopped.
Explanation: The BIOS is unable to find any logical drives
attached to any ServeRAID controllers. Therefore the ServeRAID
BIOS is not loaded.
Action: Reconnect the cable(s) attaching the hard drives to the
controller and restart the system. If performing a service
procedure, reconnect them when told to do so.
Controller Ok; Devices not responding check cables or
enclosures.
Explanation: A SCSI connection problem has been detected.
Action: Check all cables and devices attached to the ServeRAID
controller. Look for bent or missing pins on all cables and devices.
Netfinity 5500 M20 - Type 8662
323
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...