available in both the Information and
Configuration modes.
ServeRAID Mini-Configuration Program
The ServeRAID Mini-Configuration Program is a quick way
to display the current settings for the ServeRAID adapter
or controller. You also can use this program to perform a
limited set of the configuration functions without using the
ServeRAID Configuration CD.
To access the Mini-Configuration program:
1. Turn on the server. If the server already is turned on,
restart it.
2. When the ServeRAID Mini-Configuration prompt
appears, press Ctrl+i.
3. If the system contains more than one ServeRAID
adapter or controller, a selection screen will appear.
To continue:
a. Use the Up Arrow (
↑
) or Down Arrow (
↓
) key to
select an adapter or controller.
b. Press Enter.
If the system contains only one ServeRAID adapter or
controller, or after you select a ServeRAID adapter or
controller, the Main Menu appears.
Descriptions of the choices available from the Main
Menu of the Mini-Configuration program are as
follows:
View Controller Status shows the current status
of the ServeRAID adapter or controller. (See
“Viewing the controller status” for more
information.)
View Configuration shows the current
configuration information for the ServeRAID
adapter or controller. (See “Viewing the
configuration” on page 95 for more information.)
Advanced Functions lets you initialize the
configuration, import configuration from drives,
configure BIOS settings, and view the controller
and PCI information. (See “Advanced
Configuration Functions” on page 96 for more
information.)
4. Use the Up Arrow (
↑
) or Down Arrow (
↓
) key to
highlight your choice; then, press Enter.
5. Follow the instructions that appear on the screen.
6. Select Exit to leave the Main Menu.
Viewing the controller status:
When you select View Controller Status from the Main
Menu, the following information appears on the screen:
Unattended shows the current On/Off state of the
Unattended mode.
94
Netfinity Server HMM
Содержание 866251Y - Netfinity 5500 M20
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Страница 346: ...338 Netfinity Server HMM...
Страница 354: ...346 Netfinity Server HMM...
Страница 355: ...Related service information 347...
Страница 356: ...348 Netfinity Server HMM...
Страница 357: ...Related service information 349...
Страница 368: ...360 Netfinity Server HMM...
Страница 369: ...Related service information 361...
Страница 385: ......
Страница 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...