5-22
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 5 Maintenance and Alignment
5.14 PC Board Replacement Procedures
!
WARNING:
BE SURE TO USE AN ANTI-STATIC WRIST STRAP WHEN HANDLING PC BOARDS
OR IC’S TO PREVENT DAMAGE TO THE COMPONENTS.
5.14.1 Replacement of the Life Support Board
If the Life Support Board is replaced, the following procedure should be performed.
STEP 1
Turn off the transmitter and remove all power at the wall breaker.
STEP 2
Remove the two screws holding the controller assembly in place and
slide it out. It will come almost all of the way out before catching and
will then drop down in the front to about a 30 degree angle. Then
remove bracket across boards.
STEP 3
Set all jumpers on the new Life Support Board to the same locations as
the board to be replaced. There are 7 jumpers on the Life Support Board.
JP1 and JP2 select the main and alternate exciter mute as active HIGH or
LOW. Table 2-2 (in Section II) shows the proper settings for a Harris
exciter.
•
JP3 should be set from pins 2-3 for a ZHD+
•
JP4, JP5 should be set to 1-2
•
JP6 set to 2-3, for IBOC operation
•
JP7 at 1-2 for single RF Source only. For any other configurations set
at 2-3.
STEP 4
Be careful to mark and note where all cables connect to the defective
Life Support Board before removing. External Interlock and Failsafe
could also be connected to this board.
STEP 5
Install the new Life Support Board, and reconnect all wires and cables.
Be very careful not to bend the PC board when installing any wires into
the Wago block on the rear of the card. The card should be supported
from the back side due to the necessary pressure required to open the
Wago block terminals.
STEP 6
Turn on the AC at the wall breaker but do not turn the transmitter on yet.
Make sure CB1, the circuit breaker in the rear of the transmitter is also
turned on.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...