WARNING: Disconnect primary power prior to servicing.
Section 2 Installation & Initial Turn-On
Platinum Z16HD+
NOTE:
Maximum status line current is 25 mA. If the output is used to drive a small
printed circuit board type relay, check current requirements for relay coil and be
sure to install a circuit protection diode across the coil. A 1N4004 or equivalent
will work.
Figure 2-14 shows typical remote/extended control and status connections.
Figure 2-14 Typical Remote/Extended Control and Status Connections
NOTE: TB1-38 is not used for HD+ Transmitters
Not Used for HD+
Transmitters