9/15/06
888-2586-001
2-23
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation & Initial Turn-On
Platinum Z16HD+
of non-shielded wire makes a very efficient antenna for RF and transient energy. If RF
is allowed into the audio equipment, it can be rectified and may show up as noise or
feedback. Wire and cable shields should normally be connected at both ends to the
equipment chassis.
2.5.7.5
Low Voltage Power Supply and Blower
The Low Voltage Power Supply and the blower motor operate from any voltage within
the specified range of the tapping chart without re-tapping.
2.5.8
Audio Input Connections
All audio signals connect directly to the back of the exciter(s) by routing the cables
through the top of the cabinet. See the HDx-FM Exciter and FlexStar System technical
manuals for information pertaining to audio connections, input levels and adjustments.
Be sure to leave enough cable slack to allow the exciter to be pulled all of the way
out on the rack slides.
2.5.9
External and Failsafe Interlock Connections
The transmitter is shipped with two jumpers installed on TB1, the Remote Control
Interface terminal strip: TB1-7 to TB1-6(GND) is for External Interlock and TB1-8 to
TB1-10(GND) is for Failsafe.
2.5.9.1
External Interlock Connection
To use the External Interlock connection, remove the jumper between terminals TB1-7
to TB1-6(GND), then connect external interlock wires. A contact closure allows the
transmitter to operate. When the external interlock connection is opened the PA power
supplies, blower and exciter turn off, the status of the transmitter is set to off. The
external interlock wires can also be connected directly to the Life Support Board at J4-7
and J4-10 if it is desired to have the interlock completely separate from the remote
control interface. The TB1 and J4 connections are in parallel. Only one or the other is to
be used. NOTE: The transmitter will require an ON command after the external
interlock connection is restored.
!
CAUTION:
TO CONNECT TO THE WAGO BLOCK, J4 ON THE LIFE SUPPORT BOARD
REQUIRES PRESSING A SCREWDRIVER INTO THE RECTANGULAR SLOT
ON THE FRONT SIDE OF THE BLOCK SO THE WIRE CAN BE INSERTED
FROM THE REAR. BE SURE TO PROPERLY SUPPORT THE BOARD SO THAT
IT IS NOT BENT OR STRESSED IN ANY WAY WHILE INSERTING THE WIRES.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...