WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
up to full power. If a fault returns, the transmitter will simply revert back to the previous
fault condition.
NOTE:
Pressing an ON command will not erase any faults from the Diagnostics Fault
Log. Basically, any components which were shut off due to a fault will now be
turned back on, such as PAs or controllers.
Interlock
The TX_RESTART signal from U4 is gated by AND gate U6-13. This is the turn on
signal for the contactor and will only pass if U6-12 is also high. U6-12 is the Interlock
signal. To satisfy the Interlock, there must be a closed connection between J4-10 and
J4-7 (GND) on the Life Support Board (or between TB1-7 and TB1-6 on the Remote
Control Interface terminal strip). This will activate the optical isolator, U24 making
U27-11 and U33-1 both low. U27-10 inverts the signal and makes U6-12 high, allowing
the high turn on signal at U6-13 to pass to inverter U16-6. U16-11 now sends a low to
the SET input on the contactor turn on relay, K4 (the contactor is shown in the RESET
position).
The Interlock line going to U33-1 ties the interlock into the OFF command circuit.
When the Interlock is closed, this line is low and U33-1 ignores the input. If the
Interlock were opened, the line would go high which would send a high to the RESET
input on relay K4 and the main AC contactor would disengage.
Contactor Turn On Relay, K4 (Latching)
K4 is a latching relay which only needs to be pulsed to make it change positions and
will then stay in that position until the opposite input is pulsed to make it change back.
When K4 is SET, K4-13 will go high and K4-4 will go low. K4-13, the CONTACTOR-
ON-STATUS signal for the Master Controller, is AND gated with POWERFAIL and
inverted at U16-12 to become the CONTACTOR_ON(BAR) signal. This signal is sent
to the Low Voltage Power Supply Board where it activates the main contactor and the
exciter(s).
CONTACTOR_ON(BAR), K4-4
The signal at K4-4 is called CONTACTOR_ON(BAR) and ties to several places, U33-
12, U30-12, and U30-10. This signal is low when K4 is in the SET position and the
contactor is engaged.
a.
The CONTACTOR_ON(BAR) signal at U33-12 is only used during Life Support
Mode. Whenever the transmitter is on, K4-4 will be low, which holds U33-12
low. If the Master Controller has failed the MSTR-NORMAL 1 signal will also
be low. This makes the output at U33-11 and the input to U32-1 low. Once the
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...