Removal of Pallet Bolts
There are 4 bolts which must be removed in order to take the transmitter off the wooden
pallet, 2 toward the front of the cabinet and 2 toward the rear. Location of these bolts
can be verified by looking for the bolt heads underneath the pallet. If the transmitter was
shipped with the power supply removed, simply remove the power supply cover from
the bottom front of the transmitter cabinet to access the pallet bolts. However, if the
transmitter was shipped with the power supply installed, the power supply tray is
covering the bolts, so the fan assembly on the rear of the transmitter will also have to be
removed to access the rear pallet bolts (the power supply itself does not have to be
removed). Open and remove the upper rear door by lifting it off its hinges. Remove the
fan assembly by removing six screws and two nuts located around the outside edge of
the fan assembly. Slowly move the assembly to the right-hand side being careful of the
interconnect wiring. The fan assembly will rest on the pallet out of the way. The rear
pallet bolts can now be accessed under the rear of the power supply tray.
After the transmitter is off the pallet, it is also a good idea to remove the shipping
screws holding the rear of the power supply tray. This will allow the power supply to be
rolled out the front of the transmitter at a later date without having to take off the fan
assembly.
2.5.1.2
Single Phase Cabinets
The 3 phase version of the transmitter has only one cabinet, however the single phase
Z16HD+ supplies are much larger than the 3 phase counterpart and require a second
cabinet. Two supplies will be installed in the left hand cabinet with the controller and
PAs, and the other two are installed in the auxiliary or right-hand cabinet. The cabinets
may be shipped with the power supplies installed although it depends on where and
how the transmitter is shipped. The increased size of the supply is simply due to the
larger amount of filtering components and larger rectifiers necessary for the lower
ripple frequency of the single phase supply.
2.5.2
Visual Inspection
Be sure to check the connection of all cables and wires in the transmitter. Areas to check
would include:
a.
Power Supply Connections
1.
Check for loose cables and connections on the power supply trays and
loose hardware on the floor of the cabinet.
2.
Make sure the Rectifier Boards are properly seated in the connectors on top
of the transformers (3-phase version).
3.
Check the power supply and control connections (ribbon cables) to the
Rectifier Boards.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...