WARNING: Disconnect primary power prior to servicing.
Section 3 Operator Guide
Platinum Z16HD+
3.3.1
Forward Power (FWD PWR) Units of Measure
The default unit of measure for the forward power reading is percentage, with 100%
representing the nominal power output for the station. This percentage can be calibrated
to any power level using the Configuration controls in the Diagnostics System. If
desired, the forward power reading can be converted to read kilowatts by simply
pressing and holding the FWD PWR button for at least 4 seconds. After 4 seconds the
display should automatically change to indicate power in kilowatts.
3.3.2
Reflected Power (RFL PWR) Units of Measure
The default unit of measure for reflected power is VSWR. If desired, the reflected
power reading can be converted to kilowatt by simply pressing and holding the RFL
PWR button for at least 3 seconds. After 3 seconds the display should automatically
change to power in kilowatts.
3.3.3
Fault/Foldback/Interlock LED Indications
NOTE:
For Emergency conditions refer to "3.6 Emergency Operating Procedures" on
page 3-12.
Front panel LEDs can indicate normal and abnormal conditions. Typically, GREEN is
"good" and RED is "bad".
A continuously lit Fault LED indicates an active fault. If the LED is blinking it is an
indication of a previous fault conidition that is no longer present, and the tranmsitter
should be operating normally. Refer to "3.6.2 FAULT LED Illuminated" on page 3-12
for more information.
If the ZHD+ transmitter has an illuminated Foldback LED it is presently in a foldback
condition and the transmitter may be operating at a lower power or it may be folded
back to OFF. Refer to "3.6.3 FOLDBACK LED Illuminated" on page 3-12 for more
information.
The Interlock LED will illuminate if a Failsafe or Interlock loop has opened. Refer to
"3.6.4 INTERLOCK LED Illuminated" on page 3-13 for more information.
3.4
Using the Diagnostic Display
The Platinum Z Series transmitters utilizes a very unique and powerful diagnostic
system. The diagnostic system is actually your interface to the inner workings of the
transmitter. It is used for Status, Metering, Fault Logging, Configuration and even
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...