WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
Platinum Z16HD+
•
ISO_AZ, BZ, CZ AND DZ - These 4 are the ISO loads located in the middle of the
Isolation Boards. Their component designation is R9 on the Isolation Board sche-
matic.
•
ISO_AB and ISO_CD - These 2 are the ISO (reject) loads on the hybrids which are
combining the outputs of the respective Z-Planes. They are physically located above
the power blocks. Their component designation is A2A5R1 and A2A7R1 on the
Overall Wiring Diagram.
•
ISO_ABCD - This one is the ISO load on the ABCD hybrid which is combining the
outputs of the two AB and CD hybrids. It is located on the front of the Hybrid box
below the PA deck (in the power supply compartment). Its component designation is
A2A6R1 on the Overall Wiring Diagram.
All of these loads are monitored for temperature by the Master Controller and all of the
PA controllers simultaneously. The responsibility for system protection belongs to the
Master Controller, with the PA Controllers acting as backup in case of a Master failure.
6.12.22.1System ISO Foldback
The Master Controller has a foldback routine it will use to protect these system
components called ISO APC Foldback. ISO APC Foldback uses 3 thresholds, 110°C,
115°C and 130°C. If one of these 7 loads reaches 130°C the Master Controller will
switch the fan to high speed and start the foldback routine by reducing the APC voltage
at a fixed rate. If the temperature is reduced, the foldback will stop at 115°C. If the
temperature goes below 110°C the foldback will be reversed and the power will be very
slowly increased until the power output is back to normal or until the load temperature
again rises to 115°C at which point the power increase would stop. If the temperature
then rises back up to 130°C the foldback procedure will start all over. In other words,
the Master Controller is going to try and keep the load temperature between 115°C and
130°C at some maximum power output. It is important to note that no faults will be
reported in the fault log for a foldback, only the foldback indication while the over
temperature condition is present.
NOTE:
All PA and ISO temperature faults are based on actual thermistor temperatures
and/or a predicted value of temperature based on the rate of rise in temperature
over a given period of time. Therefore, a resistor temperature which is predicted
to reach 130°C will cause an overload the same as an actual reading. Due to the
prediction, it is possible to get over-temperature faults even though the actual
temperature reading is not above the threshold.
6.12.22.2System ISO Overload (Fault)
If the System ISO APC Foldback routine fails to reduce the temperature of the
offending ISO load and the temperature reaches 145°C, the Master Controller will mute
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...