5-4
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 5 Maintenance and Alignment
5.2.3.3
Cleaning the Power Supply
!
WARNING:
DISCONNECT AND LOCKOUT PRIMARY POWER AT THE AC SOURCE PRIOR TO
PERFORMING ANY CONNECTIONS, REPAIRS, OR MAINTENANCE INSIDE THE
TRASNMITTER.
The power supply can either be cleaned with a vacuum cleaner or compressed air or
both. For example, the rectifier heatsinks on top of the transformers should be cleaned
with compressed air, then after the dust settles, the rest of the compartment vacuumed.
Be very careful when moving cables to clean. Anytime a cable or wire is moved, there
is the possibility of breakage or open connections. Therefore cables should always be
moved as little as possible.
5.2.4
Blower Motor Maintenance
Current models use GE motors which have sealed bearings with no grease fittings, and
require no lubrication.