4-50
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
turn will reduce the reflected coupler output and the clamp will be removed from the
APC Voltage and the power will try to come back to normal.
Since this is happening extremely fast, once the reflected coupler output voltage
exceeds the VSWR_FB_LVL, the new APC loop will try to keep the 2 inputs to U7 the
same, preventing the reflected power from exceeding 115W. Basically, a new APC loop
(using the output from the reflected coupler instead of the forward) has been formed
which takes precedence over the forward power loop.
4.8.4
Master Controller Faults
For a complete listing of all of the faults associated with the Master Controller Board
refer to Section VI, Troubleshooting.
4.8.4.1
3 Strike Routine
The faults in the transmitter that will initiate what is called a 3 strike routine are:
•
RFL_PWR - VSWR greater than 1.5:1
•
ISO_AZ_OT - The predicted temperature of R9 on the “A” Z-Plane Isolation board
is greater than 130
o
C.
•
ISO_BZ_OT - The predicted temperature of R9 on the “B” Z-Plane Isolation board
is greater than 130
o
C.
•
ISO_CZ_OT - The predicted temperature of R9 on the “C” Z-Plane Isolation board
is greater than 130
o
C.
•
ISO_DZ_OT - The predicted temperature of R9 on the “D” Z-Plane Isolation board
is greater than 130
o
C.
•
ISO_AB_OT and ISO_CD_OT - The predicted temperature of the AB or CD
hybrid reject load is greater than 130
o
C.
•
ISO_ABCD_OT - The predicted temperature of the ABCD hybrid reject load is
greater than 130
o
C.
a.
Strike 1 - When any of the above fault conditions are met, the transmitter output
is muted (DAC_APC_REF is brought to zero) for 3 seconds (6 seconds for trans-
mitters with a Single Phase power supply). At the end of the 3 (or 6) seconds the
transmitter power is slowly ramped back up and a 10 second timer is started.
b.
Strike 2 - If another fault is detected before the 10 seconds is up, the transmitter
will again mute for 3 (or 6) seconds, start the 10 second timer again and slowly
ramp the power up again.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...