9/15/06
888-2586-001
5-3
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
SYSTEM ELAPSED TIME
Total transmitter time on.
NAME OF REPAIRMAN
Person who actually made the repair.
STATION ENGINEER
Indicates chief engineer noted and approved the transmitter repair.
5.2.3
Cleaning
Proper airflow is essential in keeping the transmitter in top working condition. If
outside air is brought into the building it should be well filtered to keep dirt out of the
building and the transmitter.
5.2.3.1
Module cleaning
The heatsinks on the modules are high efficiency, and therefore do not have large
openings for airflow and will tend to collect dirt over time. The modules should be
cleaned with compressed air on a schedule to be determined on site, depending on the
air system, filtering, humidity etc... (at least once a year). This determination can be
made either by visual inspection or by monitoring the module temperatures in the
Diagnostics Display.
!
WARNING:
THE PA MODULES ARE DESIGNED TO HANDLE VERY HIGH TEMPERATURES AND
MAY BE EXTREMELY HOT. DO NOT TOUCH THE MODULES WITH BARE HANDS
AFTER THE TRANSMITTER HAS BEEN RUNNING, ESPECIALLY IN HIGH AMBIENT
TEMPERATURE ENVIRONMENTS.
To locate the PA Temperature Monitoring press [METERING, D, B, then select the
desired Z-Plane]. Keeping a regular log of the PA temperatures versus Ambient
temperature will give a quick indication of a possible problem or that cleaning is
necessary. To check the ambient temperature reading press [METERING, D, A, C].
5.2.3.2
Cleaning the Air Filter
The indication as to when to clean or replace the air filter is basically the same as
mentioned in the previous paragraphs, mainly with the airflow indicator, but
temperatures and/or a visual inspection would also suffice. To monitor airflow press
[METERING, A, C]
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...