WARNING: Disconnect primary power prior to servicing.
Section 2 Installation & Initial Turn-On
Platinum Z16HD+
Log to find the active fault(s) and refer to Section VI, Troubleshooting
for information on how to track down the problem.
NOTE:
The HDx-FM exciter will NOT generate HD carriers unless one of the two
following condtions is met:
1.
The HDx-FM is properly connected to, and configured for the HDE-100
Exporter (this is the recommended method)
- or -
2.
The HD carriers can be internally generated, for initial testing, by making
the following HDx-FM parameter changes on the Output Setup page 1/4:
HD Carriers: ENABLED
Exgine Input: INTERNAL
Exgine Output: PATTERN
IMPORTANT:
It is very important to note that once the HDE-100 Exporter is properly connected
and configured, the following HDx-FM settings on the Output Setup page 1/4
must be made for normal HD operation.
HD Carriers: ENABLED
Exgine Input: EXPORTER
Exgine Output: NORMAL
STEP 10
Turn the transmitter back ON at LOW power. Verify that the RF source’s
power is the same as the factory test data sheet. This can affect
performance.
NOTE:
The fan will run at high speed for 1 minute then will automatically switch to low
speed provided there are no faults. Any fault will cause the fan to automatically
switch to high speed. There is also an option to force the fan speed to HIGH in
the Configuration menus of the Diagnostics Display. See Figure 2-16.
STEP 11
At this point, if there are no faults, verify that the transmitter display
readings closely resemble those on the factory test data sheet for LOW
power. If the “FAULT” LED comes on, go to the Fault Log in the
Diagnostics Display to find out which fault has been activated and refer
to Section VI, Troubleshooting. If everything looks okay, proceed to the
next step.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...