2-10
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
2.5.4.4.4 PLAT Z SERIAL
N+1 communication path between ZHD+ transmitter and HDx-FM exciter (via the
CAN buss).
2.5.4.4.5 USER REMOTE
See Table 2-4 on page 2-41 for parallel interface connections.
!
CAUTION:
ANY REMOTE OR EXTENDED CONTROL CONNECTIONS SHOULD BE
CONNECTED ONLY AFTER THE TRANSMITTER SYSTEM IS CHECKED OUT
AND FULLY OPERATIONAL.
2.5.5
3 Phase Power Supply Installation
The Z16HD+ transmitter can be configured with either a 3-Phase or Single Phase power
supply. Operation of the supplies is basically the same with both using the dynamic tap
switching for efficiency. However, their physical make-up is different and requires
separate installation procedures. The 3-phase will be discussed first, then the Single
Phase will follow. Note that some transmitters may be shipped with the power supply
installed, depending on where and how it is shipped. If the power supply was shipped
installed in the transmitter, skip to "2.5.7 Transmitter AC Connections" on page 2-19.
Before installing the power supply check the primary AC tapping on the power
transformers as outlined below.
!
WARNING:
DISCONNECT AND LOCKOUT PRIMARY POWER AT THE AC SOURCE PRIOR TO
PERFORMING ANY CONNECTIONS, REPAIRS, OR MAINTENANCE INSIDE THE
TRASNMITTER.
2.5.5.1
Power Transformer Tapping
The power transformers are tapped at the factory for the primary AC voltage specified
by the customer. This voltage should be documented in the factory test data
accompanying the transmitter and tagged at the main contactor in the rear of the
transmitter. If your measured AC voltage matches the voltage tagged at the contactor
proceed to the next step. However, if there are any discrepancies, the voltage at the site
and the transformer tapping should be verified by the installation personnel. The input
voltage and strapping chart is shown on the Overall System Block Diagram along with
the transformer schematic. Verification and/or re-tapping will require opening the
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...