background image

Data Sheet-1

LT 22

LINE TRANSFORMER

Features

•   +24 dBu Levels
•   2 Channels
•   Nickel Core “80” Ni Transformers
•   Wide Bandwidth
•   Low Distortion
•   Euroblock Connectors

General Description

The LT 22 is a line-level two channel 

isolation box. Each channel contains a low 

distortion, high output, wide bandwidth, 

nickel-core output transformer.

The LT 22 is an easy and convenient 

way to add output transformers to any line-

level equipment. The Inputs and Outputs 

may be configured as balanced or unbal-

anced as required.

The LT 22 is the quick and afford-

able answer to all jobs requiring output 

balancing or isolation transformers. The 

Euroblock connections provide maximum 

installation flexibility and cost savings.

DATA SHEET / MANUAL

WEAR PARTS:

 This product contains no wear parts.

Parameter

Specification

Limit

Units Conditions/Comments

Transformer Construction

Nickel Core Bobbin Wound

Grade “80” Ni

Turns Ratio

1:1

Primary to secondary

40 Hz Max Output Level

+24

0.5dB dBu

1% THD point

20 Hz Max Output Level

+18.5

0.5dB dBu

1% THD point

Insertion Loss

0.5

0.1

dB

DC Resistance

200

10%

Ω

Primary and secondary

Frequency Response

20-20 kHz

±1

dB

+4 dBu

Bandwidth

60 kHz

-3

dB

Half power frequency

THD + Noise

less than .005

.001

%

+20 dBu; 100 Hz-20 kHz

less than 0.15

.05

%

+20 dBu; 30-100 Hz

Unit: Agency Listing

UL/CSA

Exempt Class 2 equipment

CE-EMC

Exempt passive device

CE-Safety

Exempt extra low voltage device

Unit: Construction

All Steel

..........Size

1.65"H x 5.1"W x 4.25"D

(4.2 cm x 13 cm x 10.8 cm)

..........Weight

1 lb

(.45 kg)

Shipping: Size

3.6" x 11.75" x 7.2"

(9.5 cm x 30 cm x 18 cm)

..........Weight

2 lb

(.9 kg)

All specifications measured with 25 Ω source and 10 kΩ load

0 dBu=0.775 volts

4.225"

0.15"

2.5"

5.1"

0.775"

0.35"

1.636"

OUTPUT

INPUT

OUTPUT

INPUT

LINE

TRANSFORMER

RANE CORP.

MADE IN U.S.A.

ACN 001 345 482

1

2

LT 22

   – +

   – +

– +

– +

Отзывы: