5-8
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 5 Maintenance and Alignment
5.4.2
System Test
!
CAUTION:
SYSTEM TEST WILL CHANGE THE POWER LEVEL TO APPROXIMATELY ¼
OF THE RATED POWER.
BE AWARE THAT THE SYSTEM TEST WILL REPEATEDLY MUTE THE
TRANSMITTER WHICH WILL INTERUPT NORMAL PROGRAMMING.
The purpose of the SYSTEM test is to check the combiner configuration, cabling and
integrity. The length of time required for the SYSTEM test will be indicated on the
display. The test will reduce the transmitter power to ¼ of the rated power and will be
going through a MUTE cycle for each PA. The VSWR reading must be 1.2:1 or less
with no faults present in order to run the test. If the VSWR is too high the test will
be aborted, but nothing will be reported in the Fault Log (the abort screen will read
VSWR high). During the test the HIGH ON and LOW ON buttons will not work. The
test can be started at any time and any power level above 50%. If a fault is detected
during the test it will be aborted and the fault will be noted in the Fault Log. Also the
user can abort the test at any time by pressing the OFF button or via the test screen on
the Diagnostics Display. The results of the test will be either Aborted, Failed or Passed.
If the test fails, check the Fault Log to find out why.
To run the SYSTEM test press [HOME, MORE, TEST, C]. This will bring up the
screen in Figure 5-2. Press [D] to run the test or [C] to go back to the previous menu.
For further details, see “Self Diagnostics” portion of Section 6 in this manual.
NOTE:
The best results will be obtained from the test if it is run after the transmitter is at
its normal operating temperature. If the test does fail, it should be run at least 2
more times to verify the same fault occurs each time.
Figure 5-2 System Test Menu
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...