4-38
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
check the IDs so they know to which power supply they are connected. The controllers
will also not allow 2 IDs to be the same.
The jumper table below is also located on the Rectifier Board schematic.
4.6.4
Low Voltage Power Supply Board
The AC input to this board is dependent on the AC voltage and configuration for the
transmitter, 3-phase Delta (3 wire), 3-phase WYE (4 wire) or single phase. The same
board is used in all three cases. The AC inputs to the board come from circuit breaker,
CB1, and enter the board at J1-1 and J1-4. For the 3-phase Delta and Single Phase J1-1
is Phase A and J1-4 is Phase B (Phase C for the 3-Phase does not connect to this board).
For the 3-phase WYE J1-4 is Phase B and J1-1 is the Neutral.
Phases A and B are connected directly to the low voltage transformers T1 and T2.
Transformer T1 has dual full wave rectifiers. The T1 secondary outputs are fused by F3,
F4, F5 and F6, and are then full wave rectified for two DC outputs of approximately
+10Vdc.
NOTE:
Fuses F3 - F10 are self-resetting circuit breakers which physically look like disc
capacitors.
This voltage will vary depending on what the AC mains voltage is for the site. The
+10Vdc is filtered by C1-C6 and connected to the rectifier boards, on top of the PA
power supply transformers, in the bottom of the transmitter. Transformer T2
secondaries are fused by F7, F8, F9 and F10 before going to dual bridge rectifiers. The
rectifier outputs are filtered by C7-C10 and supply approxi20Vdc and -20Vdc
to the Rectifier Boards on the PA power supply transformers. All three voltages are
regulated on the Rectifier Boards and are sent to the Display/Backplane Board to power
the controller. For troubleshooting purposes, each of the supply outputs has a green
LED (on the board) which should be lit if the supply is working.
NOTE:
The +10Vdc, +20Vdc and -20Vdc are approximate values and will vary with the
incoming as line voltage and configuration. The normal value for these readings
is 30% to 40% higher than the label.
PS#1
PS#2
PS#3
PS#4
JP1
IN
OUT
IN
OUT
JP2
OUT
IN
IN
OUT
JP3
OUT
OUT
OUT
IN
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...