9/15/06
888-2586-001
5-23
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
STEP 7
Setting the +5V REF - with a digital voltmeter, check TP4, the +5V REF
(reference). The voltage should be 5.00V, +/- 0.01V. If not, adjust R28 to
make it so.
STEP 8
IPA Current Fault Adjustment - this adjustment only affects operation in
Life Support Mode. Adjust R23 on the Life Support Board for 1.45Vdc
+/- 0.05V at TP-31. This is sets the fault threshold to 5.0 amps of IPA
current.
STEP 9
RFL PWR Overload Adjust - this adjustment only affects operation in
Life Support Mode. Adjust R24 on the Life Support Board for 1.5Vdc at
U3-5. This sets the fault threshold for reflected power when Life
Support Mode is active.
STEP 10
Set R127 Maximum CW. This sets power output to minimum.
STEP 11
Set R128 Maximum CCW. This reduces the sensitivity of the VSWR
circuit.
!
WARNING:
TURNING R128 MAXIMUM CCW DEFEATS THE VSWR PROTECTION. THE
REFLECTED POWER CALIBRATION MUST BE COMPLETE BEFORE RETURNING
THE TRANSMITTER TO ON-AIR SERVICE.
STEP 12
Set R25 Maximum CCW.
STEP 13
Power Calibration - complete the Reflected Power Calibration and then
the Forward Power Calibration procedures located earlier in this section
then return here to finish replacement of the Life Support Board.
STEP 14
Set switch S1-9 on the Master Controller to the ON position to place the
transmitter in Life Support Mode (the fan will switch to high speed and
the front panel will go out). Adjust R25, Manual PWR REF, on the Life
Support Board for ¼ TPO on an external meter. Switch S1-9 to OFF and
the transmitter should return to normal. It may be necessary to raise or
lower power slightly.
5.14.2 Replacing the Power Supply Controller Board
Replacement of a PS Controller Board requires no analog adjustments. Set all dip
switches and jumpers to the same position as the board being replaced. If the new board
does not have the firmware ICs already installed, then the firmware will have to be
transferred from the old board. Refer to "5.16 Removing/Replacing Firmware ICs" on
page 5-30.
The following is a listing of the normal dipswitch and jumper settings:
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...