9/15/06
888-2586-001
6-19
WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
Platinum Z16HD+
6.10 Self Diagnostics
The Z Series transmitter is equipped with a set of TEST menus for testing various
internal systems. To access the TEST menus press [HOME, MORE, TEST]. This brings
you to the screen in Figure 6-4. This screen gives you 2 choices:
•
SYSTEM TEST
•
CONTROL HARDWARE
Figure 6-11 Diagnostic Test Menu
6.10.1 System Test
!
CAUTION:
SYSTEM TEST WILL CHANGE THE POWER LEVEL TO APPROXIMATELY ¼
OF THE RATED POWER.
BE AWARE THAT THE SYSTEM TEST WILL REPEATEDLY MUTE THE
TRANSMITTER WHICH WILL INTERUPT NORMAL PROGRAMMING.
The purpose of the SYSTEM test is to check the combiner configuration, cabling and
integrity. The length of time required for the SYSTEM test will be indicated on the
display. The test will bring the output level to approximately 1750W regardless of
current modulation format, and will be going through a MUTE cycle for each PA. The
test can be started at any time. The user can abort the test at any time by pressing the
OFF button or via the test screen on the Diagnostics Display.
In order for the test to run, the antenna VSWR must be 1.2:1 or less with no faults
present. If the VSWR is too high the test will be aborted. The abort screen will read
VSWR high, but nothing will be reported in the Fault Log. During the test the HIGH
ON and LOW ON buttons will not work. If a fault is detected during the test it will be
aborted and the fault will be noted in the Fault Log. The results of the test will be either
Aborted, Failed or Passed. If the test fails, check the Fault Log to find out why. To run
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...